Technical data
General data and operating conditions
General data
4
l
16
BA 13.0011−EN 1.0
4 Technical data
4.1 General data and operating conditions
4.1.1 General data
Conformity and approval
Conformity
CE
2006/95/EC Low−Voltage Directive
Approvals
UL/CSA File no. E210321
Protection of persons and equipment
Degree of protection
See nameplate
Degrees of protection only apply to horizontal installation
All unused plug−in connections must be sealed with
protective caps or dummy connectors.
Earth leakage current IEC/EN 61800−5−1 > 3.5 mA Observe stipulations and safety
instructions!
Total fault current < 100 mA
Earth−leakage circuit breakers of type B can be used.
Thermal class F (155 °C) IEC 60034 Exceeding the temperature limit weakens or destroys the
insulation
Insulation resistance IEC/EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Protective measures Short circuit on the motor side, earth fault when switching on
the mains and during operation, motor overtemperature
(input for PTC or thermal contact, I
2
t monitoring)
Permissible voltage IEC/EN 60034−25 1.5 kV peak value
10 kV/ms speed of increase
Vibration Up to 2.0 g (20 m/s
2
) without resonance excitation, e.g. of the
fan.
EMC
Noise emission
IEC/EN 61800−3
Depending on the controller, see documentation for the
controller.
Noise immunity