Technical data
General data and operating conditions
General data
4
l
17
BA 13.0011−EN 1.0
4.2 Operating conditions
Ambient conditions
Climatic
Transport IEC/EN 60721−3−2 2K3 (−20 ... +70 °C)
Storage IEC/EN 60721−3−1
1K3 (−20 ... +60 °C) < 3 months
1K3 (−20 ... +40 °C) > 3 months
Operation IEC/EN 60721−3−3
Without brake −15 °C ... +40 °C
With brake −10 °C ... +40 °C
Without power reduction
> +40 °C With power reduction see,
catalogue
Site altitude < 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue
Humidity Average relative humidity 85 %, without condensation
Electrical
The motor connection type depends on the controller
Length of motor cable
See inverter instructions
Length of cable for speed feedback
Mounting conditions
Mechanical
Mounting positions
Motor Suitable for all mounting positions
Geared motor Only for the ordered mounting position, see nameplate
ƒ Other application conditions require a power derating or torque reduction using the
factors listed in table 2 and 3 (see below).
Power derating
Power derating for other application conditions
Cooling air temperature [°C] 40 45 50 55 60
Power derating [kυ
]
1.00 0.95 0.90 0.83 0.77
Installation height above sea level
[m]
1000 2000 3000 4000 5000
Power derating [k
h]
1.00 0.92 0.83 0.77 0.67
Tab. 1