EasyManua.ls Logo

Leuze electronic MLC 520 EX Series - Page 54

Leuze electronic MLC 520 EX Series
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
Leuze electronic MLC 520 EX 54
Calculation of the effective protective field height
H
PFE
[mm] = Effective protective field height
H
PFN
[mm] = Nominal protective field height (see table 14.8)
A [mm] = Total height
B [mm] = Additional dimensions for calculation of the effective protective field height (see
table 14.9)
C [mm] = Value for calculating the effective protective field height (see table 14.9)
Table 14.8: Dimensions (nominal protective field height), weight and response time
Table 14.9: Additional dimensions for calculating the effective protective field height
Device type Transmitter and receiver Receiver
Dimensions [mm] Weight [kg] Response time [ms] acc. to resolution
Type
H
PFN
a)
A=H
PFN
+66
b)
14 mm 20 mm 30 mm 40 mm 90 mm
MLC…-600 600 666 0.75 14 12 7 7 3
MLC…-750 750 816 0.90 17 14 8 8 4
MLC…-900 900 966 1.05 20 17 9 9 4
MLC…-1050 1050 1116 1.20 23 19 10 10 4
MLC…-1200 1200 1266 1.35 26 22 12 12 5
MLC…-1350 1350 1416 1.50 30 24 13 13 5
MLC…-1500 1500 1566 1.65 33 26 14 14 6
a) H
PFN
= nominal protective field height = length of the yellow housing part
b) Total height, see figure 14.1
R = resolution B C
20 mm 1.5 mm 18 mm