EasyManua.ls Logo

Leuze electronic MLC 520 EX Series - Disclaimer; Notices for the Safe Use of Sensors in Potentially Explosive Areas

Leuze electronic MLC 520 EX Series
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
Leuze electronic MLC 520 EX 9
The company operating the machine is responsible for:
instructing the operator
maintaining the safe operation of the machine
adhering to all regulations and directives for labor protection and safety at work
regular testing by competent persons
2.4 Disclaimer
Leuze electronic GmbH + Co. KG is not liable in the following cases:
safety sensor is not used as intended.
Safety notices are not adhered to.
Reasonably foreseeable misuse is not taken into account.
Mounting and electrical connection are not properly performed.
Proper function is not tested (see chapter 9).
changes (e.g., constructional) are made to the safety sensor.
2.5 Notices for the safe use of sensors in potentially explosive areas
These notices apply for devices with the following classification:
Table 2.1: Classification of the devices
Device group Device category Equipment protection
level
Zone
II 3G Gc 2 (gas)
II 3D Dc 22 (dust)
WARNING
Safe use of sensors in potentially explosive areas!
Check whether the classification of the devices corresponds to the requirements of the application.
Safe operation is only possible if the devices are used properly and for their intended purpose.
Electrical devices may endanger the health of humans and (where applicable) animals and may threat-
en the safety of goods if used under unfavorable conditions or incorrectly in potentially explosive areas.
Observe the applicable national regulations, especially ATEX directive 94/4/EC and/or EN 60079-14,
for the configuration, commissioning, operation and recurring testing of explosion-proof systems.

Table of Contents