EasyManua.ls Logo

Leuze GS63B/6.3-S8 User Manual

Leuze GS63B/6.3-S8
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
info@leuze.com • www.leuze.com
We reserve the right to make changes ? DS_IGS63B_en_50128041-01.fm
Optical fork photoelectric sensor with 3mm
fork width and 60mm fork depth for exact
detection of labels on base material
High switching frequency and short
response time guarantee very good
repeatability
Slimline-design (reduced fork height) for
installation in a groove directly at the
dispensing edge
ALC function (Auto Level Control):
highest function reserve through
autonomous online optimization of the
switching threshold ((I)GS63B/….3…)
Storage of up to 30 teach values in the
sensor
Warning output for indicating teach or
function errors (IGS63B…)
Easy adjustment via lockable teach button
or teach input
3mm
Accessories:
(available separately)
Clamp BT-GS6X.DT
(Part no. 50128583)
Mounting device BT-GS6X.L
(Part No. 50112215)
Mounting device BT-GS6X.H
(Part no. 50123869)
Dimensioned drawing
A Label center position
D D1: horizontal connector, D2: vertical connector, D3: cable
E Mounted mounting device BT-GS6X.L (see mechanical accessories)
F Mounted mounting device BT-GS6X.H (see mechanical accessories)
G Indicator diodes
H Teach button or potentiometer
Electrical connection
/
/
/
/
Cable, 5-wire, IGS 63B only
Connector, 4-pin
/
/
/
Connector, 5-pin
(n. c.: for device version with potentiometer)
(I)GS 63B Fork photoelectric sensor
(I)GS 63B… - 02
en 2020/08/19 50128041-01
Question and Answer IconNeed help?

Do you have a question about the Leuze GS63B/6.3-S8 and is the answer not in the manual?

Leuze GS63B/6.3-S8 Specifications

General IconGeneral
BrandLeuze
ModelGS63B/6.3-S8
CategoryAccessories
LanguageEnglish

Summary

Product Overview and Features

Dimensioned Drawing

Detailed mechanical dimensions and component labels for the fork photoelectric sensor.

Electrical Connection

Wiring diagrams for 4-pin and 5-pin connectors, detailing pin assignments and voltage.

Available Accessories

List of optional mounting devices and clamps for sensor installation.

Technical Specifications

Physical Data

Details on mouth width, depth, label gap, light source, and switching frequency.

Electrical Data

Information on operating voltage, residual ripple, open-circuit current, and switching outputs.

Mechanical Data

Specifications for housing materials, optics, weight, and connection types.

Environmental Data

Ambient temperature range, protective circuits, VDE protection class, and standards.

Marking and Diagrams

Marking on the Sensor

Guidance on aligning the label tape using the sensor's 'Label center position' marker.

Performance Diagrams

Graph showing repeatability as a function of conveyor speed.

Intended Use and Safety Notes

Intended Use

Description of the sensor's function for contactless label detection.

Safety and Operation

Notes on product safety, non-personnel protection use, and operation by competent persons.

Product Ordering and Part Numbering

Order Guide

List of preferred sensor types with designations, part numbers, and comments.

Part Number Code Explanation

Breakdown of part number components for sensor configuration options.

Auto Level Control (ALC) Function

Sensor Adjustment Methods

Adjustment via Potentiometer

Procedure for manual sensor adjustment using the potentiometer and operating button.

Adjustment via Teach Button

Instructions for sensor teach-in using the device's teach button with different levels.

Teach-in Procedures

Standard Function

Default sensor operation detecting label gaps with high precision and speed.

Teach-in via Teach Button

Detailed steps for standard and sensitive teach-in modes, including dynamic and static methods.

Adjusting Switching Output Behavior

Procedure to set the output to switch in the label gap or on the label.

Teach-in via Teach Input

Teach-in with Moving Label Tape

Procedure for dynamic teach-in using a teach input with moving label tape.

Static Teach-in Process

Procedure for static teach-in using a teach input when label tape cannot be advanced.

Light/Dark Switching Adjustment

Setting the switching output behavior for light or dark detection via teach input.

Teach Value Management

Storing Teach Values

Process for storing up to 30 different teach values for various label materials.

Reading Out Teach Values

Procedure for loading stored teach values from memory.

Locking Teach Button

Method to lock the teach button via the teach input to prevent accidental operation.

Integration Control Notices

Sensor feedback signals for acknowledging teach states in external control systems.

Mechanical Accessories

Flat Mounting Device

Mounting device (BT-GS6X.L) for flat design and compatibility with GS 06 sensors.

High Mounting Device

Mounting device (BT-GS6X.H) for uniform tape height with IGS 14 sensors.

Clamp for Groove Installation

Clamp (BT-GS6X.DT) for sensor installation in a groove at the dispensing edge.

Maintenance and Durability

Maintenance Information

Recommendations for cleaning transparent parts using a soft, moist cloth.

Environmental Durability

Resistance of materials to acids, bases, UV exposure, and solvents.

Related product manuals