Only for training and service purposes
Check whether written EDID data is correct or not.
(refer to Product spec).
After writing EDID, send Elapsed Time Clear command.
(Elapsed time should not be displayed, after EDID writing)
- : Confirm periodically (in the first set of new lot, process change) whether module name and
aging time disappeared on the self-diagnostics OSD with signal cable disconnected.
If Elapsed Time Clear command isn’t executed, module name, aging time and TCO word appear
on the self-diagnostics
OSD.(Module name and aging time should not appear after writing EDID)
Make sure to do FACTORY RESET at the final process.
3.2.5.9 V-Com Adjustment
*LGD panel biz need adjusting V-COM by software
Definition: adjusting V-Com level thereby show minimum flicker
Process: By LG cmd , Check Flicker Level and If Can’t meet Flicker spec,
Adjust V-com value through IIC line of panel. If flicker level meet spec, save V-com value at
EEPROM.
Connection Diagram
The
type of Probe must be CA-P12/15 or CA-P15
V-com adjustment Spec
27MP59HT/24MP59HT
Flicker level ≤ 35
3.2.6.0. Shipping condition
Energy saving : low