LG
November 2018
55EG9600 IN-START “Power Off Status” Details (1 of 3)
55EG9600 (2015) In-Start Menu
Page 04
MODE Contents Action
POWER_OFF_BY_17VOVP 17 V Over Voltage Protect (PDP Only) Y, Z, SMPS
POWER_OFF_BY_17VUVP 17 V Under Voltage Protect (PDP Only) SMPS
POWER_OFF_BY_1SEC_POWER_OFF
CONDITION: When power button is repeatedly pressed on, CPU does not complete the
boot cycle
Main
POWER_OFF_BY_20V_DETECT
RESULT : Micom force to trigger TV power off.
CONDITION : when OLED detects a drop in Drain (depending on panel design) voltage
level (20V).
SMPS, Panel
POWER_OFF_BY_5VMNT
Power off by not detecting 5V monitoring
RESULT : Micom triggers TV power off
CONDITION : During AC on or DC on, stabilization check routine, the voltage level is
incorrect.
Y, Z, Cntl, Main, SMPS
POWER_OFF_BY_ABN
Power off by abnormal status
RESULT : Micom triggers TV power off
CONDITION : when Display port model (Nano LED, LZ9600) does not detect port cable.
Main , IR, T-Con
POWER_OFF_BY_ABNORMAL1 Power off by abnormal status Main, IR, Wifi
POWER_OFF_BY_ACDET
Power off by loss of AC-Detect
RESULT : Micom triggers TV power off
CONDITION : Power detect port drops to low while power in “on” status.
SMPS, Main
POWER_OFF_BY_AUTO_OFF
Power off by auto off function
1. When it lasts for 15 minutes that no signal and no remote key input.
2. When screen mute status lasts for 2 hours.
None
POWER_OFF_BY_CH_UPDATE_TIMER start : get channel update in warm standby (for Italy model.) None
POWER_OFF_BY_CH_UPDATE_TIMER_END end : get channel update in warm standby (for Italy model.) None
POWER_OFF_BY_CIPLUS_SEARCH_END CI+ search complete. (Log) Main
POWER_OFF_BY_COMP_END
RESULT: Power off
CONDITION: OLED Compensation (Threshold voltage degradation) completes, (OLED
up to webOS 2.0)
None
POWER_OFF_BY_COMP_FAIL
A failure has been reported to the Micom from the OLED display or Compensation was
interrupted. , (OLED up to webOS 2.0)
SW, Main, Panel
POWER_OFF_BY_COOLING Power off for cool down the OLED t-con. (OLED) webOS 3.5 or later None
POWER_OFF_BY_CPU_ABNORMAL Power off by CPU Abnormal status Main, IR, Wifi
POWER_OFF_BY_CPUCMD Power off by CPU Command Main, IR, Wifi
POWER_OFF_BY_DATA_FLASH When Micom EEPROM is initialized, log for reference of EEPROM initialization error. Main
POWER_OFF_BY_EDID_WRITE Power off by EDID write done. None
POWER_OFF_BY_EWBS Power off by EWBS function. Main
POWER_OFF_BY_FAN_CONTROL Power off by fan control Fan / Main
POWER_OFF_BY_FAN_CTRL_ERROR power off by fan control error (for OLED/STB model) Main, Fan
POWER_OFF_BY_HDMI_CEC Power off by HDMI CEC command None
POWER_OFF_BY_HOMING_COMPLETE Power off by Cable Card Update (USA only) N/A
POWER_OFF_BY_INSTOP_KEY Power off by Instop Key None
POWER_OFF_BY_INV_ERROR Power off by LCD module inverter error (OLED) SW, Main, Panel
POWER_OFF_BY_KEYTIMEOUT
Power off when TV is not turned off during a certain time
RESULT : Micom force to trigger TV power off.
CONDITION : When pressing power key while power on status, CPU does not response
within 10 seconds or send delay command.
None
POWER_OFF_BY_MAIN_WDT Main
POWER_OFF_BY_Micom_RESET Main Micom Reset None
POWER_OFF_BY_MICOM_UPDATE Power off by micom update. None