39
ENGLISH
53. Power Indicator (Command: f o)
Sets the Power Indicator Settings.
Transmission
[f][o][ ][Set ID][ ][Data][Cr]
Data 00: Off
01: On
Acknowledgement
[o][ ][Set ID][ ][OK/NG][Data][x]
** Depending upon the model, this feature may not be
supported.
54. Fan control (Command: d o)
Sets the fan mode.
Transmission
[d][o][ ][Set ID][ ][Data][Cr]
Data 00: Auto
01: On
02: Manual
03: Off
Acknowledgement
[o][ ][Set ID][ ][OK/NG][Data][x]
** Depending upon the model, this feature may not be
supported.
55. Fan Failure Check (Command: d w)
Checks for fan failures.
Transmission
[d][w][ ][Set ID][ ][Data][Cr]
Data FF: Status read
Acknowledgement
[w][ ][Set ID][ ][OK/NG][Data1] [Data2] [x]
Data 1 00: One or more fans are faulty.
01: All fans are normal.
02: The model has no fan.
Data2 00: No fan is faulty (all fans are normal).
01: 1 fan is faulty.
02: 2 fans are faulty.
03: 3 fans are faulty.
04: 4 fans are faulty.
05: 5 fans are faulty.
56. Luminance Value Read (Command: m u)
Reads luminance values.
Transmission
[m][u][ ][Set ID][ ][FF][Cr]
Acknowledgement
[u][][SetID][][OK/NG][Data1][Data2][Data3][Data4]
[Data5][Data6][Data7][x]
Data1 00 to 64: The Backlight PWM value (0 to 100)
Data2 00 to ff: The upper 1-byte of the value measured by
the CA-210.
Data3 00 to ff: The lower 1-byte of the value measured by
the CA-210.
CA-210 measurement: 0000 to ffff in hexadecimal and 0 to 65535
in decimal.
Data4 00 to ff: The upper 1-byte of the value measured by
BLU 1 sensor.
Data5 00 to ff: The lower 1-byte of the value measured by
BLU 1 sensor.
Data6 00 to ff: The upper 1-byte of the value measured by
BLU 2 sensor.
Data7 00 to ff: The lower 1-byte of the value measured by
BLU 2 sensor.
BLU measurements: 0000 to ffff in hexadecimal and 0 to 65535
in decimal.
* During final assembly, a CA-210 measurement is entered
through the calibration procedure. The default value, before
calibration, is 0.
** Depending upon the model, this feature may not be
supported.
57. BLU Maintenance (Command: m t)
Selects whether to turn on/off BLU Maintenance.
Transmission
[m][t][ ][Set ID][ ][Data][Cr]
Data 00: BLU Maintenance Off
01: BLU Maintenance On
Acknowledgement
[t][ ][Set ID][ ][OK/NG][Data][x]
** Depending upon the model, this feature may not be
supported.
58. Easy Brightness Control Mode (Command: s m)
Selects whether to turn on/off Easy Brightness Control Mode.
Transmission
[s][m][ ][Set ID][ ][Data][Cr]
Data 00: Easy Brightness Control Off
01: Easy Brightness Control On
Acknowledgement
[m][ ][Set ID][ ][OK/NG][Data][x]
* This function does not work if the current time is not set.
** Depending upon the model, this feature may not be
supported.

Table of Contents