92 2008 Product Data
14. Installation
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 100mm. The unit
should be installed as high as possible on the wall,
allowing a minimum of 200mm from ceiling.
6. Use a metal detector to locate studs to prevent
unnecessary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat
radiation from the condenser is not restricted.
2. Ensure that the space around the back and sides is
more than 300mm. The front of the unit should have
more than 700mm of space.
3. Do not place animals and plants in the path of the
warm air.
4. Take the weight of the air conditioner into account
and select a place where noise and vibration are
minimum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.
Select the best Location
More than 200mm
More than
100mm
More than 2300mm
More than
100mm
Install the indoor unit on the wall where the height from the floor is more than 2.3 meters.
More than 300mm
More than 300mm
More
than 600mm
More than 600mm
More than 700mm