- 15 -
ADJUSTMENT
Windows EDID V1.0 User Manual
Operating System: DOS, windows98, 2000, XP
1. Parallel port setting
Enter your bios, and do as followings.
a) Integrated peripheral
b) Super IO Device
c) Parallel port mode
you should set the” parallel port mode” to SPP for using the DOS EDID tool surely.
2. EDID Write
1Connect the signal line of monitor with DDC recorder.
2Choose the DDC RECORD program, and it shows on the screen, the choose the correct source base on the
monitor.
3Click “LoadFile” ,then key in the manufacturer namemodel nameproduct code, then choose the
correct model name base on the monitor.(as Fig.2)
4Scan serial No. to DDC recorder by Bar Reader, then read again in the Verify SN.
5According to the message of DDC program, when the picture as fig.1 appears, it show DDC record has finished.
Fig.1