1. MAIN UNIT FUNCTION
• DISPLAY
1) C/O Model (high quality LCD remote controller supplied)
Operation Indicator
On while in appliance operation, off while in appliance pause
Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)
Sleep Timer Indicator
On while in sleep timer mode, off when sleep timer cancel or appliance operation pause
Timer Indicator
On while in timer mode (on/off), off when timer mode is completed or canceled
Comp. Running Incidator
While in appliance operation, on while in outdoor unit compressor running, off while in compressor off
2) H/P Model (high quality LCD remote controller supplied)
Operation Indicator
On while in appliance operation, off while in appliance pause
Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)
Sleep Timer Indicator
On while in sleep timer mode, off when sleep timer cancel or appliance operation pause
Timer Indicator
On while in timer mode (on/off), off when timer mode is completed or canceled
Defrost Indicator
Off except when hot start during heating mode operation or while in defrost control
Cooling Mode Operation
When the intake air temperature reaches 0.5°CC below the setting temp, the compressor and the outdoor fan
stop.
When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp=> Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp-0.5°C
While in compressor running, operating with the airflow speed set by the remote controller. While in compressor
not running, operating with the low airflow speed regardless of the setting.
Healthy Dehumidification Mode
When the dehumidification operation input by the remote controller is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C Intake Air Temp => 25°C
24°C Intake Air Temp < 26°C => Intake Air Temp-1°C
18°C Intake Air Temp < 24°C => Intake Air Temp-0.5°C
Intake Air Temp < 18° => 18°C
While in compressor off, the indoor fan repeats low airflow speed and pause.