When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the
intake air temperature and the setting temperature.
Airflow Speed Selection
The airflow speed of the indoor fan is set to high, medium, low, or chaos (auto) by the input of the airflow speed
selection key on the remote controller.
On-Timer Operation
When the set time is reached after the time is input by the remote controller, the appliance starts to operate.
The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
If the appliance is operating at the time set by the timer, the operation continues.
Off-Timer Operation
When the set time is reached after the time is input by the remote controller, the appliance stops operating.
The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.
If the appliance is on pause at the time set by the timer, the pause continues.
Off-Timer <=> On-Timer Operation
When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is
carried out according to the set time.
Off-Timer Operation (Simple LCD Remote Controller)
When the set time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote controller while in appli-
ance operation, the operation of the appliance stops.
If the operation of the appliance is stopped while in the off-timer mode, the off-timer mode is canceled.
The timer LED is on when the off-timer mode is input. When the off-timer mode is canceled, it is off.
Sleep Timer Operation
When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote controller while in
appliance operation, the operation of the appliance stops.
While the appliance is on pause, the sleep timer mode cannot be input.
While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increas-
es by 1°C After another 30 min elapse, it increases by 1°C again.
When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the
low.
When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the
medium.