EasyManua.ls Logo

LG LS363HLV - User Manual

LG LS363HLV
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SINGLE ZONE EXTENDED PIPING
WALL MOUNTED INSTALLATION MANUAL
Single Zone Extended Piping
LS243HLV, LS303HLV, LS363HLV

Other manuals for LG LS363HLV

Question and Answer IconNeed help?

Do you have a question about the LG LS363HLV and is the answer not in the manual?

LG LS363HLV Specifications

General IconGeneral
BrandLG
ModelLS363HLV
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Instructions

Wiring Safety

Safety guidelines and instructions for electrical wiring.

General Installation Guidelines

Outdoor Unit Location Selection

Guidelines for choosing the optimal location for the outdoor unit.

Required Outdoor Unit Clearances

Specifies minimum clearance requirements for proper unit operation and service.

Required Indoor Unit Clearances

Specifies minimum clearance requirements for the indoor unit.

Refrigerant Safety Standards; Device Connection Limitations

Refrigerant Safety Standards

Discusses safety standards and maximum allowable refrigerant concentration.

Device Connection Limitations

Outlines limits for refrigerant piping length and elevation.

Refrigerant System Engineering

No Pipe Size Substitutions

Prohibits substituting specified pipe sizes to ensure system reliability.

No In-line Refrigeration Components

Lists prohibited in-line components that can affect system performance.

Flaring and Brazing Procedures

Flaring and Brazing Procedures

Covers methods for performing flared and brazed refrigerant connections.

Refrigerant Piping Connections

Outdoor Unit Connections

Step-by-step instructions for connecting piping to the outdoor unit.

Indoor Unit Connections

Procedures for connecting piping to the indoor unit.

Insulation

Refrigerant Piping System Insulation

Requirements for insulating all refrigerant piping for safety and efficiency.

Minimum Refrigerant Pipe EPDM Insulation Wall Thickness Requirements

Details minimum EPDM insulation wall thickness based on location and pipe size.

Electrical System Installation

Safety Guidelines; Connections and Specifications

Safety guidelines and specifications for electrical system connections.

Power Wiring; Communication Cable Connections

Instructions for making power and communication cable connections.

Final Installation Procedures

Triple Leak; Pressure Test

Procedure for performing a triple leak and pressure test on the refrigerant piping.

Deep Evacuation Procedure

Steps for performing a deep evacuation of the refrigerant piping system.

Triple Evacuation Test

Procedure for conducting a triple evacuation test for system integrity.

Troubleshooting

Cautions for Refrigerant Leaks

Refrigerant Leaks

Discusses refrigerant safety, allowable concentration limits, and leak calculations.

Related product manuals