34
Single Zone Extended Piping Wall Mounted Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
REFRIGERANT PIPING CONNECTIONS
Indoor Unit Connections
Figure 32: Removing the Bottom Panel from
Indoor Unit.
Figure 33: Propping Open the Piping / Drain Hose Holder (L-bracket).
Cover
Accessing and Positioning the Indoor Unit Piping / Connections
1. Unsnap the piping / drain hose holder (L-bracket) out from the indoor unit chassis. Prop
it open between the indoor unit chassis and installation plate to separate the bottom of
the indoor unit from the wall. This will allow for more working space.
Installation
Plate
Drain Hose
Holder
L-bracket
Figure 34: Back of Indoor Unit.
2. Remove the piping port cover.
3. Position the piping by unfolding and bending the piping slowly
downward first as shown, then to the left or right (pre-chosen
following installation guidelines and application needs) as shown.
Secure piping with the piping holder.
Do not bend the piping directly backwards or to the left or right
sides without bending it downward first; this will damage the indoor
unit piping.
Do not forcibly press the refrigerant piping onto the bottom
frame or the front grille; this will damage the indoor unit piping and
/ or indoor unit frame.
Ensure the piping is straight. Do not kink the piping; this will
damage the indoor unit and piping.
Figure 35: Bending Piping at Rear of Indoor Unit.
Figure 36: Improper Piping Bending.
Right Side
Piping
Piping / Drain Hose Holder
Left Side Piping
Rear
Piping
Figure 37: Keep Piping Straight; Avoid Kinks.
Unfold
slowly
downward
Bend from
downward
position
Removing the Indoor Unit Bottom Panel
To access the indoor unit piping port connections, and to make the indoor unit installation
procedure easier, open the front panel, and remove the bottom panel removed first.
1. Fully open the front panel. The control panel can be accessed on the bottom right side
of the front of the indoor unit.
2. Pull the screw cap(s) at the bottom of the indoor unit.
3. Unscrew the five (5) screws (depending on the indoor unit model) at the bottom of the
chassis panel.
4. Remove the bottom panel, being careful not to scratch the main horizontal vane.
Set aside the bottom panel to re-install after all procedures are complete.