Installation of Indoor, Outdoor Unit
8 Multi Type Air Conditioner
How to fix installation plate
Type 1.
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with 
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
Drill a Hole in the Wall