26
EN
CAUTION
• During air purification operation, do not touch
top side of the product. (Static electricity may
be generated by anion created from dust
collection ionizer.)
• Do not put metal objects near the appliance.
(Static electricity may be generated by anion
created from dust collection ionizer.)
NOTE
• Air purification single operation is the operation
with low energy consumption.
• During air purification single operation, wind
direction function can be used, but temperature
control function cannot be used.
• During cooling operation or dehumidification
operation, if you want air purification single
operation, press power button to turn off
the product, and press AIR PURIFY button.
• Ionizer and filter components may be different
for each model.
Checking Overall
Cleanliness
It displays the indoor cleanliness.
1
Turn the appliance on.
2
During the operation, if you press PM
SENSOR button, you can check the indoor
cleanliness in each level.
a
Overall cleanliness color display
b
Dust size dust concentration display
• Dust concentration is displayed in unit of
1 within 8~999 μg/m
3
. Dust concentration
referred to the data sheet of the sensor
manufacturer.
• Dust concentration may continuously change
according to the change of the indoor
environment.
• Overall cleanliness color is displayed based
on the highest contamination level among fine
dust(PM10), ultra fine dust(PM2.5), and super
ultra fine dust(PM1.0).
• Overall cleanliness color is displayed in 4 levels
according to the indoor contamination level.
• If dust concentration is high, the difference
between the displayed dust concentration and
the actual dust concentration may become
bigger.
Color Level
Display standard (μg/m
3
)
Super
ultra
fine dust
(PM1.0)
Ultra fine
dust
(PM2.5)
Fine
dust
(PM10)
Green
Green
(Good)
12 or less 12 or less 54 or less
Yellow
Yellow
(Normal)
13 - 35 13 - 35 55 - 154
Orange
Orange
(Bad)
36 - 55 36 - 55 155 - 254
Red
Red
(Very bad)
56
or more
56
or more
255
or more
27 / 206