15
EN
PREPARATION WORK
Before starting installation, decide on the position of
the indoor and outdoor units, taking into account the
minimum space reserved around the units.
WARNING
Do not install your air conditioner in a wet room
such as a bathroom or laundry etc.
The installation site should be 250 cm or more
above the floor.
Installation of the Mounting
Plate
1
Always mount the rear panel horizontally and
vertically.
2
Drill 32 mm deep holes in the wall to fix the
plate.
3
Insert the plastic anchors into the hole.
4
Fix the rear panel on the wall with provided
tapping screws.
5
Be sure that the rear panel has been fixed firmly
enough to withstand the weight.
Ø 50
NOTE
The shape of the mounting plate may be different
from the one above, but installation method is
similar.
Drilling a Hole in the Wall for
the Piping
1
Make the piping hole (Ø 55) in the wall at a slight
downward slant to the outdoor side.
2
Insert the piping-hole sleeve into the hole to
prevent the connection piping and wiring from
being damaged when passing through the hole.
5 mm
Indoors Outdoors
WARNING
The hole must slope downwards towards the
exterior.
NOTE
Keep the drain pipe down towards the direction of
the wall hole, otherwise leakage may occur.