21
EN
Circuit Breaker
Between the power and the appliance, install a
certified circuit breaker. The interrupting device
should be equipped to properly block all power
sources.
Air Conditioner
Main Power Source
Circuit
Breaker
Model Circuit Breaker
W09TI
16 A
W09TE
W12TI
W12TE
W18TI
W24TI
NOTE
• Check whether the current capacity of the
selected cable and wiring exceeds the rated
capacity of the recommended circuit breaker.
Connecting the Pipes
Screw the flare nuts to the outdoor unit coupling with
the same tightening procedures described for the
indoor unit.
To avoid leakage, pay attention to the following
points:
• Tighten the flare nuts using two wrenches. Pay
attention not to damage the pipes.
• If the tightening torque is not sufficient, there
will probably be some leakage. With excessive
tightening torque there will also be some leakage,
as the flange could be damaged.
• The surest system consists in tightening the
connection by using a fix wrench and a torque
wrench: in this case use the table on page 24.
Connection pipes
Liquid tap
Gas tap
Gas valve
Liquid valve
Tap
Flare nuts
Protection caps
Indoor unit
Service
port nut