7. TROUBLE SHOOTING
7-1.BEFORE SVC CHECKING
â– Be careful of electric shock or disconnecting the parts while trouble shooting.
â– Voltage of each terminal in 113-127 V~ and DC while applying an electric current.
7-2.QC TEST MODE.
â‘
Pressing Option (Left) and Soil Level button simultaneously.
â‘¡
Press the Power button, while the above condition.
â‘¢
Press the Start/Pause button as follows.
Number of times the
Start/Pause button is pressed
7-4.HOW TO KNOW THE WATER LEVEL FREQUENCY
Press the Water Plus and Option(Left) button simultaneously.
ex) 241 : Water level frequency = 241× 10 kHz
-1
= 24.1 kHz
The digits means water level frequency (10
-1
kHz)
sutatS yalpsiDtnioP kcehC
None Turns on all lamps and locks the door.
1 time Tumble clockwise. rpm (42~50)
)56~55( mpr.nipS deeps woLsemit 2
137)( mpr.nipS deeps hgiHsemit 3
4 times Inlet valve for prewash turns on. Water level frequency (229~255)
5 times Inlet valve for main wash turns on. Water level frequency (229~255)
6 times Inlet valve for hot water turns on. Water level frequency (229~255)
7 times Tumble counterclockwise. rpm (42~50)
8 times
Heater turns on for 3 sec. Water temperature
9 times
Circulation pump turns on.
Water level frequency (0 ~ 255)
10 times
Drain pump turns on.
Water level frequency (0 ~ 255)
-ffOsemit 11