6)
Replacement of Rotor and Stator
① Disassemble rotor nut with boxer (M18) or spaner.
(Tighten to greater than 200 kgf/cm or xxx foot-
pounds.)
② Disassemble the rotor and pull it out, as shown in
the drawing.
③ Remove the screws and detach the water guide
from the tub.
④ Disconnect the hall sensor and stator housing
before disassembling the stator.