ERROR DECISION CAUSE FOR ERROR
BASIS OCCURRENCE
REMEDYERROR
LID is opened in the
course of
intermittent spin,
normal spin or
processing
reservation.
SIGNAL
continuously ringing.
Water Pressure
Switch is off.
AUTO OFF relay
switch is out of order.
In the second QC
MODE, the following
message is
displayed.
DOOR
OPEN
PRESSURE
SENSOR
AUTO OFF
LAUNDRY
AMOUNT
SENSOR
Lid is opened during intermittent
spin or normal spin?
Lid is opened while processing
reservation?
PRESSURE SENSOR is bad or
bad contact.
Is placed magnetic in LID-B?
Connector the pressure
sensor (Pressure Switch) or
BLUE (BL) 3 pin connector to
PWB assembly has bad connection.
Pressure sensor
(Pressure Switch) is bad.
(In the initial state of QC TEST
MODE, the number on the
DISPLAY is less than 63 or
more than 70)
BLUE (BL) 1pin connector to
PWB assembly has bad connection.
Check MOTOR, CLUTCH,
V-BELT, CONDENSOR.
Check over all connectors if
they have bad connection.
Close the lid.
Close the lid.
Check and replace
PRESSURE SENSOR.
Change the LID-B.
Correct the connector contact.
Replace pressure
sensor (Pressure Switch).
Correct the connector contact.
Change PWB assembly.
Adjust or replace those parts.