4 - SETTING THE OPERATING PARAMETERS
4.2.7 “SR-Speed Relax”
“SR-Speed Relax” parameter stands for the yarn consumption threshold
(expressed in m/min) below which the Tension Relaxation” function is actuated
at the value set and entered in parameter “TR-TensionRelax”.
If no speed limit is set in the “SR-Speed Relax” parameter screen (which
means it is OFF), all relax features are inhibited.
This value can be set as follows:
“OFF” to inhibit whatever relax feature.
“-F1” to enable “Wheel Turn Relax” at 10 m/min in speed.
“-F2” to enable “Wheel Turn Relax” at 30 m/min in speed.
Values ranging from 3 to 999 m/min to actuate “Tension Relax” at a speed
smaller than the set one.
The default setting of this value is “OFF”.
By simultaneously pressing the “+” and “-” buttons the increase Step value is
set. The increase value will alternatively change from 0.1 to 1.0. By holding
pressed the “X” button for 3 seconds, the minimum value that the parameter
can take is set.
Use + or - to set the
desired value
Scroll the parameters by
using + or -