4.2.8 “LC- Length Count”
“LC- Length Count counts the amount of wire that has been consumed by
the feeder. A value in metres is set which corresponds to the yarn length at
the end of which the device has to stop (indicating a machine STOP).
As soon as this value is set, the feeder will start measuring the amount of
wire it consumes. When the pre-set value is reached, the Spin unit will stop
the machine with a count-end alarm E:LC End” (the orang light will blink).
Yarn Consumption
In theyarn consumption” page, you can see:
1. The counter reference value
2. The current count value
3. If the function is enabled (LC icon visible at the bottom)
LC End
This alarm can be reset by pressing X in the main page. When the alarm
is reset, the counter is reset, too.
By simultaneously pressing the keys + and , the increase Step value is
set. The latter may vary from 1 to 100 to 10000.
By holding the X key pressed for 3 seconds, the counter will be reset and
the text OFF will be displayed.