49
Chapter 11 - Maintenance
Turn the key switch to the platform control and pull the red emergency stop buttons of the ground and
platform operation controls.
Lower the platform to the collapsed position...
Press the drive function select button.
Select a point (such as the touchdown point on the wheel) of the machine as the visual inspection reference
from the test line.
Drive the machine at maximum speed and release the lever at the moment when the reference point
passes the ground test line.
Measure the distance between the reference point and the test line. Result: the machine stops within the
specied stopping distance. No action is required. Result: the machine does not stop within the
specied stopping distance.
Notice: the brake must be valid within the permissible traceability range of the machine.
Replace the brake and repeat the above process from step 1.
B-8 Driving speed test in transport status
1) This check must be carried out every 250 hours or every quarter, whichever comes rst.
2) The normal driving function is essential for safe operation. With the driving function, a fast and stable
response must be given to the operator. No delay, vibration and abnormal noise may be
emitted during normal operation and the driving process.
3) Do the driving test on a solid and level surface without any obstruction.
Draw two lines with a distance of 10 m on the ground, i.e. the start and nish line.
Turn the key switch to the platform control and pull the red emergency stop buttons of the ground and
platform operation controls.
Lower the platform to the collapsed position...
Press the drive function select button.
Choose a point on the machine as the visual inspection reference for the start and nish line.
Drive the machine at the maximum speed and start counting when the reference point
passes the starting line.
Keep driving at maximum speed and note the time when the reference point crosses the nish line.
See the specication.
B-9 Driving speed test from transport status
1) This check must be carried out every 250 hours or every quarter, whichever comes rst.
2)
The normal driving function is essential for safe operation. With the driving function, a fast and stable response
must be given to the operator. No delay, vibration and abnormal noise may be emitted during normal
operation and the driving process.
3) Make sure that the driving speed test is carried out on a solid and level surface without any obstruction.
Draw two lines on the ground with a distance of 10 m, i.e. the start and nish line.
Turn the key switch to the platform control and pull the red emergency stop buttons of the ground and
platform operation controls.
Press the lift function selection button.
Press the on / off button.