Chapter 8 - Function test
8.1 Prohibited from operating unless
The safety principles of the machine are understood and implemented.
1) Dangerous conditions are avoided.
2) The inspection before operation is always carried out.
The function test is understood and followed up for the next step.
3) The workstation has been checked.
4) A function test is always carried out before use.
5) The machine is used for its designed purpose.
8.2 Basic principles
1) The function test is aimed at nding a defect before the machine is used.
2) The operator must test all machine functions according to the step-by-step instruction.
3) Do not use the defective machine. Indicate that the machine is defective and do not use this machine.
4) Only qualied service technicians may repair the machine according to the regulations of the manufacturer.
5) After maintenance, the operator must perform the inspection for operation and the function test again before
the using the machine.
8.3 Function test
1) Carry out the function test on a rm and horizontal ground without any obstacle.
2) Make sure the battery is connected.
8.4 On the ground control
1) Set the red emergency stop buttons on the platform control and the ground control to the "OFF" position.
2) Engage the ignition switch on the ground control.
3) Pay attention to the LED reading device on the platform controls.
8.5 Emergency stop test
1) Push the red Ground Emergency Stop button to the "OFF" position. Result: all functions are disabled.
2) Set the red emergency stop button to the "ON" position.
8.6 Test of lift/lower function and initiate function
The central alarm system controls the buzzer to control alarms at different frequencies.
The lowering alarm sounds 60 times per minute. If the exit protector does not reach the location, the buzzer sounds
180 times a minute. The buzzer sounds 180 times per minute for overload.
1) Switch the key switch to the platform control or OFF position.
2) Push the lever in the upward direction and keep the dead man switch pressed. Result: platform does not rise.
3) Activate the ignition switch to the ground control position.
4) Push the lever in the upward direction and keep the dead man switch pressed. Result: the platform rises.
5) Push the lever to the direction down and keep the dead man switch pressed. Result: the platform goes down.
When the platform goes down, the lowering alarm goes off. The platform drops to a height of 2 m and then
stops lowering.
6) Push the lever downwards and hold down the dead man switch again. Result: the platform drops to the lowest
position. If the platform goes down, the lowering alarm goes off.