    Sheryl YatesAug 14, 2025
    What to do if my Lienuis Dehumidifier is not operating?
    • K
      Kristin PrinceAug 14, 2025
      First, ensure the power cord is securely inserted into the wall outlet. If it still doesn't work, empty the water tank and reinstall it correctly. Also, make sure that the operating temperature is within the range of 41-95°F.
  • F
    Francis ByrdAug 17, 2025
    What to do if my Lienuis OL20-D068C Dehumidifier has water leakage?
    • C
      christopherjonesAug 17, 2025
      Before transporting your Lienuis Dehumidifier, always empty the water tank. Also, check the drain hose for any kinks or bends, and straighten the hose to avoid any traps.
  • A
    Amanda AvilaAug 20, 2025
    Why is my Lienuis Dehumidifier making excessive noise?
    • R
      Riley BarryAug 20, 2025
      Ensure the unit is placed on a horizontal and firm ground. Check for any loose, vibrating parts and secure them tightly. Note that some noise from flowing refrigerant is normal.
  • S
    Sara VasquezAug 25, 2025
    What to do if my Lienuis OL20-D068C shows error code E2?
    • A
      Adam RogersAug 25, 2025
      The error code E2 means that the humidity sensor is dampened or has failed. You should clean or replace the humidity sensor.
  • J
    jason39Aug 27, 2025
    What to do if my Lienuis OL20-D068C shows error code CL?
    • D
      Dr. Margaret MorganAug 27, 2025
      The error code CL is normal. The compressor and fan will stop working under this condition.
  • E
    Erin FinleyAug 30, 2025
    What to do if my Lienuis OL20-D068C shows error code CH?
    • D
      Daniel SmithAug 30, 2025
      The error code CH is normal. The compressor and fan will stop working under this condition.
  • G
    Gavin RodriguezSep 3, 2025
    What to do if my Lienuis OL20-D068C shows error code LO?
    • M
      Michael StantonSep 3, 2025
      The error code LO is normal. The compressor and fan will stop working under this condition.
  • S
    Sharon ConradSep 6, 2025
    What to do if my Lienuis OL20-D068C shows error code HI?
    • B
      Bobby AcevedoSep 7, 2025
      The error code HI is normal. The compressor and the fan will keep running under this condition.
  • A
    Amanda StarkSep 10, 2025
    Why is there little condensate formation in my Lienuis OL20-D068C?
    • S
      Susan CaseySep 10, 2025
      The air filter might be clogged by dust, so clean the air filter. Also, check if the air inlet or outlet is obstructed and remove any obstructions. If the environment is low temperature, the machine will defrost, which is normal. Also, ensure that the humidity level is set below the current humidity value.

Summary

1 BEFORE YOU BEGIN

Unit Symbols and Warnings

Explains symbols and warnings for safe unit identification and understanding.

Essential Safety Guidelines

Crucial safety rules to follow before and during initial use of the appliance.

2 IMPORTANT SAFETY TIPS

Electrical Safety Precautions

Guidelines for safe electrical connections, grounding, and power cord handling.

Operational Safety Rules

Key safety measures for operating the dehumidifier, avoiding hazards.

Servicing and Refrigerant Safety

Safety protocols for servicing the unit, especially regarding refrigerant handling.

3 PRODUCT OVERVIEW

Dehumidifier Components Explained

Visual diagram identifying all parts of the dehumidifier.

4 INSTALLATION

Optimal Unit Placement

Recommendations for selecting the best location for unit installation.

Safe Operation Environment

Requirements for a safe and effective operating environment for the dehumidifier.

5 OPERATION

Control Panel and Modes

Explanation of the control panel layout, power, and mode selection.

Timer, Fan, and Humidity Settings

How to adjust timer, fan speed, and humidity target settings.

Child Lock Functionality

Guide to activating and deactivating the child lock feature for safety.

DRAINAGE

Manual Tank Emptying

Instructions for emptying the water tank manually.

Continuous Drainage Setup

Procedures for setting up continuous drainage using a drain hose.

6 MAINTENANCE

Air Filter Cleaning

Steps for cleaning the air filter to maintain performance and prevent damage.

7 TROUBLE SHOOTING

Temperature and Operation Limits

Understanding operational limits related to ambient temperature.

Problem Diagnosis and Solutions

A guide to identifying and resolving common unit malfunctions and error codes.

8 DECOMMISSIONING

Proper Storage Procedures

Guidelines for storing the dehumidifier for long periods.

Responsible Disposal Practices

Instructions for safe and environmentally friendly disposal of the appliance.

9 SAFETY PRECAUTIONS

Usage and Handling Safety Tips

Safety advice on placement, operation, and handling the unit.

Maintenance and Drainage Safety

Safety considerations for cleaning, filter care, and drainage.

Power and Transportation Safety

Safety measures for unplugging, power failures, and moving the unit.

10 CUSTOMER SERVICE

Warranty and Contact Details

Information on product warranty coverage and how to contact customer service.

Overview

This document is a user manual for the Lienuis dehumidifier, model OL20-D068C. It provides comprehensive information on the device's function, technical specifications, usage, and maintenance.

Function Description

The Lienuis dehumidifier is designed to remove excessive moisture from the air, thereby reducing relative humidity to protect buildings and their contents from the adverse effects of high humidity. It uses R134a as the refrigerant, which is environmentally friendly, has no damaging influence on the ozone layer (ODP), and a negligible greenhouse effect (GWP). The unit is intended for indoor residential applications.

Important Technical Specifications

  • Model: OL20-D068C
  • Refrigerant: R134a (flammable, heavier than air)
  • Operating Temperature Range: 41°F to 95°F (5°C to 35°C)
  • Minimum Room Size for Installation: Exceeds 4 m²
  • Sound Pressure Level: Below 36 dB (A-weighted)
  • Power Source: Must be of equal voltage, frequency, and rating as indicated on the product identification plate.
  • Humidity Adjustment Range: 30% - 80% RH (in 5% increments)
  • Timer Setting: 0 - 24 hours (in 1-hour increments)
  • Continuous Dehumidify Mode: Runs at high fan speed (adjustable), humidity setting cannot be adjusted.
  • Auto Mode: Fan and compressor operate based on environmental humidity relative to set humidity (starts if environmental humidity > set humidity +3%, stops if environmental humidity < set humidity -3%). Both fan speed and humidity are adjustable.
  • Sleep Mode: Target humidity is 60%. After 10 seconds of no operation, most indicator lights and the display screen turn off, except for the sleep mode, power, and child lock indicators. If the water tank is full in sleep mode, the machine does not alarm but the "Water Tank Full" indicator light turns red.

Usage Features

The dehumidifier features a control panel with several buttons for operation:

  • POWER: Turns the unit on/off. When turned on, the operation indicator lights up, default fan speed is high, and default humidity is 50%. When turned off, the running indicator light goes off, the compressor stops immediately, and the fan shuts down after a 30-second delay.
  • MODE (M): Switches between "Auto" and "Continuously dehumidify" modes.
  • TIMER: Sets, checks, or cancels the timing function (0-24 hours).
  • FAN: Switches between high and low fan speeds. Fan speed is only adjustable in Auto mode.
  • HUM: Adjusts the target humidity (30%-80% in 5% increments) and timing value (0-24 hours in 1-hour increments).
  • CHILD-LOCK: Press and hold for 3 seconds to activate/deactivate. When active, the indicator light is on, and other buttons are inoperable.

Drainage: The unit offers two methods for water removal:

  1. Manual Draining: Emptying the water tank manually. When the tank is full, the machine buzzes 5 times, and the "Water Tank Full" indicator light illuminates. The unit will stop operating until the tank is emptied and reinstalled correctly.
  2. Continuous Draining: Attaching a drain hose to the drain outlet for gravity-fed drainage. The drain pipe must be straightened, its height must be lower than the drainage outlet (at least 10 cm), and it must not be submerged in water to prevent "Air Lock."

Safety Precautions:

  • Always keep the unit upright for 24 hours before first use to prevent internal damage.
  • Ensure proper grounding with a three-prong plug. Do not use extension cords or adapter plugs.
  • Operate in an ambient temperature between 41°F and 95°F.
  • Do not use outdoors.
  • Maintain at least 30cm of free space around the unit for proper air circulation.
  • Avoid installing near heat sources, in direct sunlight, or in areas with excessive dust or poor ventilation.
  • Do not operate if the unit is dropped, damaged, or malfunctioning.
  • Do not insert fingers or objects into air outlets/inlets.
  • Empty the water tank before moving the device.
  • Ensure the water tank is correctly fitted for proper operation.
  • A 3-minute time delay protects the compressor before resuming dehumidification.

Maintenance Features

  • Air Filter Cleaning: The air filter should be cleaned every two weeks. Dust accumulation restricts airflow, reduces efficiency, and can damage the unit.
    1. Switch off the unit and remove the air filter.
    2. Rinse the filter under running water or use a vacuum cleaner to remove dust.
    3. Reassemble the air filter.
    • Do not operate the unit without an air filter.
  • Water Tank Cleaning: If the water tank is dirty, rinse it with clean water. Avoid using detergents, steel wire balls, chemical dust removers, diesel, benzene, diluents, or other solvents, as these can damage the tank and cause leaks.
  • Storage: For long-term storage (more than a few weeks), clean and thoroughly dry the unit.
    1. Switch off and unplug the unit.
    2. Drain any remaining water.
    3. Clean and dry the filter in a shaded area.
    4. Collect the power cord at the water tank.
    5. Re-install the filter.
    6. Store the unit in an upright position in a ventilated, dry, non-corrosive, and safe indoor place.
    • Important: The evaporator inside the machine must be dried out completely before packing to prevent component damage and mold. This can be done by unplugging the unit and placing it in a dry open area for several days, or by setting the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.

Disposal: Releasing refrigerant into the atmosphere is strictly forbidden. Electrical appliances should not be disposed of as unsorted municipal waste. Contact local government for information on available collection systems. Improper disposal can lead to hazardous substances leaking into groundwater, affecting health and well-being.

Lienuis OL20-D068C Specifications

General IconGeneral
BrandLienuis
ModelOL20-D068C
CategoryDehumidifier
LanguageEnglish