Introduction 
The DVI-HDCP-TPS-TX95 and DVI-HDCP-TPS-RX95 are DVI 1.0 and HDMI 1.4 compatible 
long distance extenders. The units offer bi-directional RS-232, Infra-Red (IR), and Ethernet 
pass-through  all  on  the same CAT5e...CAT7*  cable  that  carries  the  uncompressed HDMI 
video and audio signal. 
Typical standalone application - the transmitter and the receiver 
 
Installation of a transmitter and a receiver 
1.  Power off all devices. (Installing with powered devices may harm them.) 
2.  Check the RS-232 switches (2) on the TX and RX; they must be in Normal position. 
3.  Set the desired TPS link mode with the TPS link mode switch (3) on the front of the units. 
4.  Set the desired TX remote power** mode with the jumpers on the right side of the TX. 
5.  Connect a CATx* cable to the TPS OUTPUT (7) on the TX. 
6.  Connect the video source and the desired accessory devices to the TX. 
7.  Set the desired RX remote power** mode with the jumpers on the right side of the RX. 
8.  Connect the other end of the CATx* cable to the TPS INPUT on the RX. 
9.  Connect the video sink and the desired RS-232, IR and Ethernet devices to the RX. 
10. Supply the extenders with 12V 2A DC. If the remote power is enabled on both sides only one 
local adaptor can be used. Else both units must be powered by local adaptors. 
11. Supply the other connected units. 
*  CAT7 SFTP cable is always recommended. 
**  Never connect any third party device to the extender with remote powering. 
Warning! The TPS remote powering must be used only with 95 series TPS extenders and 
MX-TPS matrix boards. Using it with other devices may damage both units. 
Warning! Do not connect any device to the TPS connector unless you are sure they are 
compatible. Connecting incompatible devices with similar connectors may cause harm to 
the devices. 
 
Front and rear view 
 
Info:  Transmitter and receiver have the same construction and connectors. 
Remote power options 
The TPS extenders can be powered remotely by its extender pair or a TPS matrix board. This 
feature can be enabled or disabled with jumper settings. Switch off the extenders. On the 
right  side  of  the  enclosure  a  small  section  (in  the  blue  box)  can  be  removed.  Loose  the 
screws and remove the plate. Jumpers are under it. To enable the remote power function 
place the jumper block onto all the pinheads. To disable it place the jumper block onto the 
upper  line  pinheads  only.  In  case  of  enabled  remote  power  on  both  extenders  the  local 
adaptor can be placed at any side. To better understand the remote power options see the 
Figure 1 on the page 4.