EasyManuals Logo

Linak DESKLINE CBD4 User Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Page 9 of 24
Description of the DESKLINE
®
DL1A system
Each DESKLINE
®
DL1A actuator is equipped with a motor and parallel/memory drive is ensured by means of software in the
CBD4/CBD5/CBD6 that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which
ensures a soft start and stop when adjusting the desk.
The DESKLINE
®
DL1A system range contains the following products:
1 control box CBD4/CBD5/CBD6
1 single DL1A or 2, 3, or 4 parallel
1 exchangeable mains cable
1, 2, 3, or 4 motor cables
1 DP1U/DPF1M (if memory function is required) DP1C/WDPL/DPT/DPF1C (if memory function and display is required) or 1
DPA/DPB/DP1K/DP1V/DPF1K (if only up/down is required.)
Options:
Possibility of running extra actuators (LA31 with hall)
Application of the DESKLINE
®
DL1A system:
Irrespective of the load the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets,
must NOT be exceeded as this will result in a superheating of the motor, the brake and the spindle nut. Exceeding the duty
cycle will result in a dramatic reduction of the life of the system.
Maximum load for each DL1A: 1600 N
Maximum load for a system with CBD4 400 W: 3200 N
Maximum load for a system with CBD4 600 W: 4800 N
Maximum load for a system with CBD5 500 W: 3200 N
Maximum load for a system with CBD6 375 W: 2400 N