What to do if my Lincoln Electric Welding System has low output even though the contactor closes?
- JJohnny MurraySep 1, 2025
If the Lincoln Electric Welding System machine input contactor closes but has no or low output, and the open circuit voltage should be 67 to 71 volts, check the electrode or work lead for looseness or breakage and repair connections. Also, check for an open transformer primary or secondary circuit and repair it. Ensure the supply line fuse isn't blown and replace it if it is, checking the fuse size. See if the input line is grounded, causing single-phase input, and repair the input to the machine if so. Verify input leads are connected to the contactor and connect them if they aren't. Also, check the latching resistor R3 for being open and replace it, checking leads to the resistor and repair if defective.