Lincoln List of Lubricants
6001a02
IMPORTANT
Absolute cleanness is essential when
handling lubricants. Impurities will remain
suspended in the lubricant and cannot
settle. This will result in damage to the
lubrication system and thus to the bear-
ing.
The Quicklub pump can dispense commercial greases up to
NLGI grade 2 or mineral oils of at least 40 mm²/s (cST) at
operating temperature.
The proven lubricants (see following tables) have been
tested by us with regard to their transportability and bleeding
behavior. We can recommend them for an application up to
the indicated minimum delivery temperature in Quicklub
lubrication systems by Lincoln GmbH. During the tests these
lubricants did not cause any damage due to incompatibility
with the material used by us. The composition of the lubri-
cants, their behavior during the transport and their compatibil-
ity with other material are not known to us.
The lubricants we recommend on the basis of the manufac-
turer’s data sheet (see following tables) can be used in our
lubrication systems up to the indicated minimum delivery
temperature.
Lubricant recipes may change. In case of doubt, send your
request for more information to the manufacturer of the cen-
tralized lubrication system. This refers in particular to lubri-
cants with more than 3% graphite that are transportable in
lubrication systems only conditionally.
The lubricants released by us have not been tested with re-
gard to their long-term behavior.
6001a02
IMPORTANT
The manufacturer of the centralized
lubrication system can accept no liability
for:
- damages due to the use of greases that
are not or only conditionally transport-
able in centralized lubrication systems.
- damages on parts of the centralized
lubrication system caused by chemical
or biological changes of the lubricant
used.
- damages due to the incompatibility with
other materials.
The liability is limited to transportable
lubricants in centralized lubrication sys-
tems.
6001a02
IMPORTANT
Use lubricants with solid matter additives only after having consulted the manufacturer of the sys-
tem!
Proven lubricants
Manufacturer Designation Thickener Min. delivery temperature
AGIP AUTOL Universal grease Li-12-OH-stearat -15 °C
ARAL Long-term grease H Li-12-OH-stearat -15 °C
AUTOL Top 2000 Ca-complex -10 °C
AUTOL Top 2000 W Ca-complex -20 °C
BP C1 Multipurpose grease Ca -20 °C
BOSCH-REXROTH Dynalub 510 Li -15 °C
BOSCH-REXROTH Dynalub 520 Li -20 °C
ELKALUB GLS 135/N2 Li -15 °C
FUCHS-LUBRITECH Stabil Eco EP2 Li/Ca -25 °C
FUCHS Renocal FN 745 Ca-12-OH-stearat -25 °C
FUCHS Renocal FN3 Ca -20 °C
FUCHS Renolit LZR 2 H Li -20 °C
FUCHS Renolit HLT 2 Li -25 °C
MOBIL Mobilith SHC 100 Li-complex -25 °C
MOLYKOTE TTF 52 inorganic thickener -30 °C
OPTIMOL Longtime PD 2 Li-12-OH-stearat -20 °C
OPTIMOL Olit CLS Li/Ca -15 °C
RHENUS Norlith KSP 2 Li + Li-12-OH stearat -15 °C
RHENUS Norlith MZN 2 Li -15 °C
SHELL Retinax EPL 2 Li-12-OH-stearat -10 °C
SHELL Retinax CSZ Li/Ca -35 °C
WESTFALEN Gresalit ZSA 2 Li-12-OH-stearat -15 °C