EasyManua.ls Logo

Linde E 30/600-02 - User Manual

Linde E 30/600-02
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
With Electric Motors
336 804 3001 GB
E 20 - 02 / E 25 - 02 / E 30 - 02
E 20/600 - 02 / E 25/600 - 02 / E 30/600 - 02
Operating Instructions
0704
Linde Fork Lift Truck
e336-02/01

Table of Contents

Questions and Answers

  • D
    daniel26Aug 9, 2025
    What to do if my Linde Forklifts truck does not start?
    • H
      harrislisaAug 10, 2025
      If your Linde Forklifts truck doesn't start, several issues could be the cause. First, check if the battery is discharged and charge or replace it if necessary. Ensure all electrical connections are tight, especially at the battery terminals, and coat them with non-acidic grease. Verify that the overhead guard is correctly locked. Finally, inspect the fuses and replace any that are blown.
  • M
    mhowellAug 16, 2025
    How to troubleshoot abnormal noise in Linde E 30/600-02 Forklifts?
    • C
      Crystal WhiteAug 16, 2025
      Abnormal noise in your Linde Forklifts can stem from several causes. Start by checking the suction filter for restrictions and clean or replace it. Inspect suction hoses for leaks, and if oil foams, tighten the hose connections. If these steps don't resolve the issue, the hydraulic pump may be damaged, or seals may be faulty, leading to air intake, in which case you should have it inspected by your authorised distributor. Also, ensure you're using the correct oil viscosity and that the oil level in the tank is adequate; change the oil and replenish if needed.
  • J
    Jeffrey GrahamAug 25, 2025
    Why is there no or too low pressure in the Linde Forklifts system?
    • S
      scottelizabethAug 25, 2025
      If you're experiencing no or low pressure in your Linde Forklifts system, several factors could be responsible. Check for pump suction faults, which may be noisy, and change or replenish the oil. Pump failure, pressure valve issues (such as valves not closing or valve seat damage) can also be the cause, and you should have it repaired by distributor’s mechanic. Inspect the pipeline for breaks or leaks, replacing the pipe or tightening connections as necessary. Also, using oil with low viscosity can lead to high leakage losses, so change the oil and use the specified viscosity.
  • D
    Donna TuckerSep 1, 2025
    What causes the hydraulic oil temperature to be too high in Linde E 30/600-02?
    • T
      Timothy McbrideSep 1, 2025
      High hydraulic oil temperature in your Linde Forklifts can be caused by pump failure or leaking valves, in which case you should have it repaired by a workshop. Also, check the oil level and replenish if it is too low.

Summary

Operator Interface and Controls

Composite Instrument Functions

Explains dashboard warning lights and indicators.

Safety and Pre-Operation Procedures

General Safety Rules

Essential safety precautions and guidelines.

Pre-Operation Checks

Daily and initial inspection procedures.

Forklift Truck Operation

Driving and Direction Control

Forward, reverse, and reversing procedures.

Braking System Operation

Details on service, foot, and handbrakes.

Mast and Attachment Control

Using the joystick for mast and attachments.

Loading and Transporting Loads

Procedures for picking up and moving loads.

Maintenance and Servicing

Troubleshooting Guide

Common Troubles and Remedies

Guide for identifying and fixing problems.

System Diagrams

Linde E 30/600-02 Specifications

General IconGeneral
Load Capacity3000 kg
Power TypeElectric
Voltage80 V
Battery Voltage80 V
Mast TypeTriplex