Section 6
Page 49
Service Training
Menu 3: Display options
This menu helps select and parameterise the information visible on screen:
- The display format for date and time Choose: European(*) / Anglo-Saxon
- The choice of display of the hour meter Choose: Displayed (*) / Non-displayed
- The choice of display of error messages Choose: Enabled(*) / Disabled
- The choice of language and logo Choose: - English Linde
- English Lansing
- French Fenwick
- French Linde
- German Linde
- Spanish Linde
- Italian Linde
- Dutch Linde
- Wheel position screen indicator Choose: Enabled(*) / Disabled
Menu 4: Battery parameters
The discharge indicator must be compulsorily parameterised according to the battery characteristics.
1) CHOICE OF BATTERYTYPE
Various discharge curves are stored in the multifunction indicator memory:
1 Battery model: Lead acid standard battery (Varta, Fulmen, Oldham, Fenwick) (*)
- Standard control for lead acid battery.
2 Battery model: Battery PZs (Deta)
- Setting for the Hawker leak proof batteries (gel).
3 Battery model: Battery with increased capacity (PZs)
- To reserve for the trucks equipped with large capacity battery, with a long discharge duration
4 Battery model: Battery without service (Gel)
- Preferably use the model no. 2 or
- Consult the battery manufacturer to get the characteristics.
2) RESET VOLTAGE/CHARGED BATTERY NO-LOAD VOLTAGE
Possible choices:
2.00 2.03 2.06 2.09 (*) 2.12 2.15 2.18 2.21 2.24 2.27 2.3 V.
(*): Standard setting
Note:
- The battery no-load voltage must be greater than the value selected to unblock the multifunction
indicator.
- The reset voltage can be slightly lowered if the indicator does not reset for a charged battery.
(*) By default