EasyManua.ls Logo

LineEye LE Series - 1.4 Explanation of Each Part [LE-110 SA]

LineEye LE Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
ڦ Connect to TTL interface 
Connect appropriate signals of UART, I2C and SPI to the TTL port of analyzer
using attached probe cable.
ڧ External Trigger Terminal
External trigger input level is LVTTL (3.3V). External trigger output is open
collector output type and pulled up in 5V by 10KΩ in the analyzer.
Attached 5-wire TTL prove can be used for connection of external trigger. To
use the TTL proves for both TTL and external trigger, prepare additional one.
 
[Trigger Function] (P20)
5wire TTL probe (LE-5LS)
If the target devices are easily affected by radiation noise from the
analyzer, try to use the shielded cable and add the ferrite core on the
cable.
TTL port
1
2
9
10
MIL box type 10pin header
*1
Cable color
Signal Name Pin
Input/
Output
LE-5LS
TXD, SDA of I2C, SDO of SPI
1 I/O
*2
Brown
RXD, SDI of SPI 3 I Red
RTS, SS(CS) of SPI
5 I/O
*2
Orange
CTS, SCL of I2C, SCK of SPI
7 I/O
*2
Yellow
Signal ground 9 - Green
Signal ground 2 -
IN: Trigger input 4 I
OT1: Trigger output 1 6 O
OT2: Trigger output 2 8 O
PWR: Power for external
*3
10 -
* 1 2.54mm pitch. Equivalent to "HIF3FC-10PA-2.54DS(71)" of
HIROSE Electric.CO
.
,LT D.
* 2 It is used for output of simulation, except SPI slave
simulation (SS and SCK are inputs).
* 3 TTL voltage (max. 30mA) is outputted when simulating.