ڦ Start and Stop Measurement
Touch [RUN] to start the specied test function and touch [STOP] to stop it.
When the analyzer is set to DTE, The TXD line means the data is transmitted from the
analyzer. When the analyzer is set to DCE, the RXD line means the data is transmitted from
the analyzer.
ڧ MANUAL Mode
Checking the data from the connected device on the display, you can transmit
the preset data which you registered in advance by touching [0] to [F] or
[SHIFT]+[0] to [SHIFT]+[D].
While putting [SHIFT], the control guide for preset data is displayed.
It can output break signal by [END/X].
You can specify the interval of each data, on/o of repeated transmission, and the interval of
data frame.
ڧ FLOW Mode
This unit becomes the transmission side or reception side, and stats the
simulation of ow control using X-ON/OFF and control lines.
When "Send test" is set, it can display the data of transmission between the
start of transmission and the interruption request for 16 times.
In "Receive test", you can specify
the number of reception data until
the transmission interruption
request is issued and the time until
the restart request of transmission is
sent.
ڧ ECHO Mode
Received data will be returned
inside the analyzer and returned to
the sender. This mode is used
for testing of devices such as
display terminals and
communication terminals.
When "Loop back" is set,
data can be returned in bit units.