BERT (Bit Error Rate Test) Function
ڦ Measurement Start and Stop
Select the test mode, test pattern, and on/off of RTS-CTS flow control in
advance.
By pressing [RUN] it starts transmission of the specified test pattern and
compares the received data with the test pattern. Then it measures the bit error
rate etc. in compliance with ITU-T G.821 and displays them on the screen. It
stops measurement by [STOP].
Set the synchronization method (ASYNC or SYNC/BSC) and the communication speed at
the "protocol" and "speed" in the conguration. For the other items, only the data bit and
stop bit settings are valid for ASYNC, and only the clock settings is valid for SYNC/BSC.
Item Contents Range of measurement
Savail
Effective time since the 󳞛rst syn-
chronization was established
0 ~ 9999999(sec)
Receive bit
Number of received bits during
synchronization establishment
0 ~ 9999999 ~ 9.99E9
Error bit Number of bit errors 0 ~ 9999999 ~ 9.99E9
Bit error rate Bit error rate 0.00E-0 ~ 9.99E-9
Sync loss Number of loss of synchronization 0 ~ 9999
Receive block
Number of received blocks during
synchronization establishment
0 ~ 9999999 ~ 9.99E9
Error block Number of blocks with bit errors 0 ~ 9999999 ~ 9.99E9
Block error rate
Block error rate 0.00E-0 ~ 9.99E-9
Error second
Time when bit error was detected
during Savail
0 ~ 9999
%E.F.S. Errored second rate (%) 0.000 ~100.000(%)