4. Use the bearing plate wrench (or a socket driver) to remove the screws that hold the
front bearing plate to the meter housing.
5. Remove the screws that hold the rear bearing plate to the housing.
Removing Corroded Rotor Gears
Follow this procedure to remove corroded gears:
1. On the back of the meter housing, remove the screws that hold the rear bearing plate to
the housing using the bearing plate wrench (or a socket driver). The number of screws
will vary depending on meter size.
2. Replace all three rotor gear screws, without washers. Screw them halfway onto each of
the rotor ends.