DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 3
1 The Regulation of Safe Usage:
(1) Before Connecting to Loads:
Individual channel must be set dimming or switch function before turning on.
The non-dimming lamp may be damaged in dimming function.
(2) Dimming Output:
DX-1210/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 are leading-edge dimmers.
DX-1210T is a trailing-edge dimmer.
Some loads/lamps might not compatible to leading-edge or trailing-edge dimmer. Please
check the manual of the load before connecting.
(3) Maximum Capacity-1:
For testing (about 30 minutes)
DX-1210/DX-1210T: Maximum output of individual channel is 10A;
DX-1220/DX-1220AF: Maximum output of individual channel is 25A;
DX-1230: Maximum output of individual channel is 30A:
For testing (about 10 minutes)
DX-630: Maximum output of individual channel is 30A;
DX-640: Maximum output of individual channel is 40A:
(4) Maximum Capacity-2:
For several hours usage (theater or stage)
DX-1210/DX-1210T: maximum output of individual channel 10A ;
DX-1220/DX-1220AF: maximum output of individual channel 16A ;
DX-1230: maximum output of individual channel 25A ;
DX-630: maximum output of individual channel 30A ;
DX-640: maximum output of individual channel 35A :
(5) Maximum Capacity-3:
DX-1210/DX-1210T: maximum output of individual channel 10A;
DX-1220/DX-1220AF: maximum output of individual channel 12A;
DX-1230: maximum output of individual channel 18A;
DX-630: maximum output of individual channel 20A;
DX-640: maximum output of individual channel 30A;
Works for 24/7 (hotels or restaurants)
(6) Environment :
Temperature: under 35°C
Case inside temperature: under 45°C
Humidity: 40% - 80%
www.m-s-v.eu