DX-1210/DX-1210T/DX-1220/DX-1220AF/DX-1230/DX-630/DX-640 [EUM-O] 17
4-5-4 Display Voltage Input
The function is to display AC voltage input.
..
4-5-5 Display Internal Temperature
..
When the internal temperature is over 34°C , the fans start to work 1 minute and stop 1 minute
in turn.
When the internal temperature is over 37°C , the fans turn on continuously.
When the internal temperature is over 63°C , all output will be stopped until the temperature is
under 60°C . In this case, please check whether the dimmer is overloaded.
4-6 SET Functions
Press "SET" key in turn and the LED will display 5 functions as follows:
1. Dimmer warm-up 0% - 6.0%.
2. Dimming or switch (non-dim) modes
3. Fader time: 0.1 SEC - 30 MIN.
4. Dimming curves.
5. Maximum wattage limit setting
4-6-1 Dimmer Warm-up
...
Press【►】: Increase channel.
Press【◄】: Decrease channel.
Press【▲】: Increase dimmer- warm up value.
Press【▼】: Decrease dimmer- warm up value..
Press【CAN】: Return
Warm-up function of a channel will be invalid if the channel is set to switch mode (non-dim) .