If your air conditioner is not fitted with a supply cord and a
plug, a
If your air conditioner is permanently connected to the fixed
wiring and have a leakage current that may exceed 10 mA,
The installation must be done by professional referring to
theInstallation instructions.
The wiring must be done by qualified electrician according
to the electrical safety requirements.
The customer should have a qualified power supply which
coincides with the tag of air conditioner, the normal voltage
should be in the range of 90-110% of its rated voltage.
The air conditioner must be well grounded, the switch of the
main power of air-conditioner must be reliably grounded.
n all-pole switchmust be installed in the fixed wiring
and the distance between contacts should be no less than
3.0 mm.
leakage protector must be installed in the fixed wiring,
operating current of which shall not exceed 30 mA.
The power supply circuit should have leakage protector and
air switch of which the capacity should be more than 1.5
times of the maximum current.
Guide for customer
Notices
The air conditioner must be installed on well strong
supporter.
The appliance shall be installed in accordance with
national wiring regulations.
Fix the machine firmly, otherwise it will produce
abnormal noise and vibration.
Install the outdoor unit in the place where it wouldnt
disturb your neighbour.
The method of connection of the appliance to the
electrical supply and inter connection of separate
somponents, please see the electric connection
elements shart which stick on the machine.
Is the power supply cord is damaged, it must be
replaced by the manufacture or its service agent or
a similar qualified person.
After installation, the power plug should be easily
reached.
Installation Guide
- 9 -