© Copyright LM Technologies Ltd Page 23 of 41
www.lm-technologies.com
User Manual for “LM068_BLE_Peri_0204” FW
viii. If the setting is OFF and user issues command to make the setting
OFF, then ERR response is received otherwise OK response is
received. Same thing applies for ON setting.
ix. Below messages shows the possible scenarios:
at*addr=?at*addr=?
REP*:ADDR=Static,Public,0002-5b-555555
OK
at*UpdateName=?at*UpdateName=?
OK
REP*:UpdateName=ON
at*nAme=?at*nAme=?
OK
REP*:NAME=LM068_BLE_Adapter55
at*nAme=TestNameat*nAme=TestName
OK
at*name=?at*name=?
OK
REP*:NAME=TestName55
at*updatename=offat*updatename=off
OK
at*updatename=?at*updatename=?
OK
REP*:UpdateName=OFF
at*name=TestNameat*name=TestName
OK
at*name=?at*name=?
OK
REP*:NAME=TestName
7.2.4 “AT*ECHO”\r\n
i. Query and set command
ii. Echo of AT commands
iii. Echo query: “AT*ECHO=?”\r\n
iv. Echo query report: “REP*:ECHO=ON” or “REP*:ECHO=OFF”
v. Echo enable command: “AT*echo=on”
vi. Echo disable command: “AT*echo=off”
vii. Default Echo: “ON”
7.2.5 “AT*RESP”\r\n
i. Query and set command
ii. Query command: “AT*RESP=?”\r\n
iii. Response query report: “REP*:RESP=ON” or “REP*:RESP=OFF”
iv. Response enable command: “AT*RESP=on”
v. Response disable command: “AT*RESP=off”
vi. Default Response: “ON”
vii. When response is ON, the LM device responds as “OK” or “ERR” to
every command string before sending report/response of the
command.
viii. When response is OFF, the LM device will not provide “OK” or
“ERR” reply to any AT command. This might not be helpful to