YarnMaster PRISMA
3.3.1 DM clearing
NSLT
Thick
Diameter threshold value ID 0–15 1.04 – 10
Threshold value for fault length ID 0–15 0 – 128 cm
Thin
Diameter threshold value ID 0–7 0.30 – 0.96
Threshold value for fault length ID 0–7 1.0 – 128 cm
NSLT cluster
Thick
Diameter threshold value ID 0–4 1.04 – 10.0
Threshold value for fault length ID 0–4 0 – 128 cm
Thin
Diameter threshold value ID 0–4 0.3 – 0.96
Threshold value for fault length ID 0–4 1.0 – 128 cm
Yarn count channel
Mass deviation ID 0–4 ±3 – ±50 %
Threshold value for fault length ID 0–4 10 – 50 m
Short count channel
Mass deviation ID 0–4 ±3 – ±50 %
Threshold value for fault length ID 0–4 1 – 10 m
OffLimit alarm
Monitoring of textile and technical events
5 different “alarm” settings can be defined
Class alarm
Monitoring of NSLT classes
“Alarm” setting can be defined for all yarn fault classes