EasyManua.ls Logo

Loepfe YarnMaster PRISMA - Page 41

Loepfe YarnMaster PRISMA
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
YarnMaster PRISMA
www.loepfe.com 41
Contact Loepfe Support
Display LZE Messages Cause Measures
AL 40
F-sensor activated,
but F-sensor not
detected.
Measuring field F sensor acti-
vated, but not configured in
Flash or CPLD
- Change the settings of the TC
type of the group
- Replace TK
AL 41
P-sensor activated,
but P-sensor not
detected.
Measuring field P-sensor acti-
vated, but not configured in
Flash or CPLD or loose contact
plug from P-sensor
- Change the settings of the TC
type of the group
- Replace TK
AL 42
Sensing head tem-
perature above
temperature thresh-
old.
Threshold exceeded, tempera-
ture > 85 °C from I²C tempera-
ture sensor
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 43
I²C blocked Fatal error on internal I²C serial
data bus
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 44
DRV knife reel
failed
Digital input signal of the knife
reel missing, > 200 ms
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 45
Sensing head in-
compatible
At least one TC hardware com-
ponent with installed firmware
not compatible
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 46
Knife not available Knife available but not config-
ured in Flash or CPLD or loose
contact connector from knife
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
Contact OEM or Loepfe Support
Display LZE Messages Cause Measures
AL 50
DRV knife power
supply failed.
Threshold exceeded, power
supply for knife > 200 ms (toler-
ance 10 %)
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 51
DRV external volt-
age supply failed.
Limit value exceeded, power
supply 5 V for > 5 consecutive
samples (tolerance 5 %)
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 52
NTP signal check
failed
> 10 s NTP pulse not detected
during yarn run
- Reset alarm >5 s TK Press re-
set test button
- Replace TK
AL 53
Spindle does not
respond
After a cut, the spindle does not
respond for 15 s
- Reset alarm >5 s TK Press re-
set test button
- Replace TK

Related product manuals