Liberty
Wood Stove
Owner's Manual
Freestanding Stove
Mobile-Home Approved
Alcove Approved
Hearth-Stove Approved
Save these instructions for future reference
SAFETY NOTICE:
If this appliance is not properly installed, a house fire may result.
For your safety, follow the installation directions. Contact local
building or fire officials about restrictions and installation
inspection requirements in your area.
Copyright 2011, T.I.
$10.00 100-01164
4110912
Listed
Tested to: U.L. 1482

Table of Contents

Questions and Answers

  • A
    Aaron BarnesAug 15, 2025
    Why kindling does not start and fire smolders in Lopi Liberty Stove?
    • A
      Ashley RodriguezAug 16, 2025
      If the kindling in your Lopi Stove doesn't start and the fire smolders, try these solutions: Open the air control to provide more airflow. If you haven't used enough starter paper, add more newspaper. If the flame isn't getting enough air, create a small crack in the door to improve ventilation.
  • J
    Judith MataAug 18, 2025
    Why is smoke entering the room when I start my Lopi Wood stove?
    • W
      William EdwardsAug 19, 2025
      Smoke may enter the room during start-up of your Lopi Wood stove due to several reasons. First, ensure the air control is open. A cold air blockage may also be the reason; try burning a piece of newspaper to establish a draft. Finally, if the flame isn't getting enough air, even a small crack in the door can help.
  • H
    handradeAug 21, 2025
    What to do if my Lopi Wood stove does not burn hot enough?
    • J
      Jennifer GarciaAug 21, 2025
      If your Lopi Wood stove isn't burning hot enough, several factors could be at play. Ensure the wood isn't wet. Also, check that the air control is fully open and not stuck by sliding it back and forth. Insufficient draft could also be the culprit; adding more pipe or a draft-inducing cap might help.
  • M
    Melinda FrancisAug 25, 2025
    What to do if smoke enters the room while reloading my Lopi Wood stove?
    • R
      Robert HoustonAug 25, 2025
      If smoke enters the room while reloading your Lopi Wood stove, make sure to open the air control before opening the door. Insufficient draft may also be the cause; adding more pipe or a draft-inducing cap may help.
  • J
    jasondillonAug 27, 2025
    What to do if the blower on my Lopi Wood stove does not run?
    • D
      Daniel HernandezAug 27, 2025
      If the blower on your Lopi Wood stove isn't running, it might be normal if the stove hasn't reached its operating temperature yet; the blower typically starts after 15 to 30 minutes. If the stove is hot, check the household breaker or fuse to ensure it's working correctly, as a lack of electricity could be the issue.
  • N
    Nicole JohnsonAug 30, 2025
    How to fix a Lopi Wood stove when the kindling does not start and the fire smolders?
    • M
      mathew94Aug 30, 2025
      If the kindling in your Lopi Wood stove isn't starting and the fire is smoldering, start by opening the air control. If you haven't used enough starter paper, add more newspaper. If the flame isn't getting enough air, even a small crack in the door can make a difference.
  • W
    Wendy MoranSep 3, 2025
    Why is my Lopi Liberty not burning hot enough?
    • E
      edwardsanthonySep 3, 2025
      If your Lopi Stove isn't burning hot enough, several factors could be at play. Ensure the air control is fully open and not stuck by sliding it back and forth. Insufficient draft could also be the culprit; adding more piping or a draft-inducing cap might help. Finally, check your wood; wet wood can prevent a hot burn. For more details on selecting appropriate wood, see the 'Selecting Wood' section.
  • K
    Karen OrtizSep 5, 2025
    How to stop smoke from Lopi Liberty entering room during start-up?
    • B
      Bruce RoblesSep 5, 2025
      If smoke enters the room during the start-up of your Lopi Stove, try the following: First, ensure the air control is open. If there's a cold air blockage, burn a piece of newspaper in the stove to establish a draft. If the flame isn't getting enough air, create a small crack in the door to provide additional ventilation.
  • C
    christopherpriceSep 8, 2025
    What to do if smoke enters room while reloading Lopi Liberty Stove?
    • D
      David RamirezSep 8, 2025
      If smoke enters the room while reloading your Lopi Stove, make sure to open the air control before opening the door. Insufficient draft may also be the cause; consider adding more piping or a draft-inducing cap to improve the draft.
  • M
    Michael ShepherdSep 12, 2025
    Why is the blower on my Lopi Stove not running?
    • M
      michaelporterSep 12, 2025
      If the blower in your Lopi Stove isn't running, it could be due to a couple of reasons. First, it's normal for the blower to take 15 to 30 minutes to start as the stove needs to reach a certain temperature. If it still doesn't run, check your household breaker or fuse to ensure it's working properly, as the electricity supply to the blower may be cut off.

Summary

General Safety Precautions

General Safety Warnings

Crucial warnings regarding operation, fuel, clearances, and handling.

Mobile Home Installation Safety

Specific safety rules for installing the stove in a mobile home.

Appliance Maintenance and Care Safety

Safety guidelines for cleaning, repairs, and general appliance upkeep.

Stove Installation Guide

Safety Notice for Installation

Critical warning about installation risks and consulting local authorities.

Planning the Installation

Guidance on planning the stove's installation, including permits and professional help.

Stove Installation Considerations

Detailed considerations for various installation types and configurations.

Floor Protection Requirements

Specifications for non-combustible flooring needed around the stove.

Stove Placement Requirements

Rules for positioning the stove and maintaining safe clearances.

Clearances

Specific minimum distances required between the stove/connector and combustibles.

Chimney Connector Requirements

Guidelines for selecting and installing the chimney connector pipe.

Chimney Requirements

Specifications for the chimney system, including types and connections.

Chimney Termination Requirements

Rules for the safe termination of the chimney above the roof.

Outside Air Requirements

Conditions and methods for connecting outside air for combustion.

Alcove Installation Requirements

Special installation rules and clearances for alcove placements.

Mobile Home Requirements

Specific installation and safety mandates for mobile homes.

Appliance Operation

Safety Notice for Operation

Reiterates safety for operation and emphasizes following manual instructions.

Before Your First Fire

Steps to verify installation and prepare for the initial fire.

Over-Firing the Stove

Warnings and advice on preventing and identifying over-firing conditions.

Starting a Fire

Tips and warnings for safely and effectively starting a fire.

Adjusting the Burn Rate

Guide on using the air control to manage the stove's burning speed.

Troubleshooting

Common issues, causes, and solutions for stove operation problems.

Appliance Maintenance

Creosote - Formation and Need for Removal

Understanding creosote buildup and its removal to prevent chimney fires.

Warranty Information

Conditions & Exclusions

General conditions and exclusions that apply to the warranty.

Appliance Listing Label

Mobile Home and Reduced Clearance Installations Require

Requirements for mobile home and reduced clearance installations.

Lopi Liberty Specifications

General IconGeneral
TypeWood Stove
Maximum Burn TimeUp to 12 hours
Maximum Log Length24 inches
ConstructionSteel
EPA CertifiedYes
Blower IncludedOptional
Firebox Size2.9 cu. ft.
FinishMetallic black