2.2.1 Check the resistance between the motor phases
• Configure your multimeter
o Choose resistance –
measurement
o Insert the measuring tips into
the provided sockets (black to
COM and red to Ω)
• The measurement is easier and safer by
using crocodile clips
• Connect the measuring clips to the
motor phases (3 different steps – L1 to
L2, L2 to L3 and L3 to L1)
Check whether the resistance between the motor phases is on the same level. The following list gives
a rough resistance value of the motor phases separated by the different motor types. The value is
depending a lot on several conditions (accuracy of the multimeter/measuring with or without
submersible cable/etc.). It is more important that the resistance is on the same level.
These given values are rough values without the submersible cable.
Resistance, measured value:
Tolerance: ±0.2 Ω