Position the controller out of direct sunshine.
This will reduce the chances of the controller
switching o from overheating.
Note: The pump is not equipped with a non-re-
turn valve which may be required for certain
applications.
Getting started
Setting up your pump
Connect a hose or pipe to the pump outlet.
Fix the controller properly on a wall or the back-
side of a PV module.
Connect the motor cables.
Connect either accessories or jumpers to A1 and
A2. Input A1 has a 15 min delay in the case dry
run is detected.
Connect the solar (PV) cable last.
Position the PV modules facing the sun, avoid
shading.