Smart Pump Range
Installation, operation
and maintenance manual
e-SVE VME e-HME
Software Version 101.04
Cod.001080136EN rev.D ed.02/2018

Table of Contents

Questions and Answers

  • M
    Mrs. Patty CunninghamSep 10, 2025
    What to do if the pressure is below the minimum threshold in my Lowara e-HME Water Pump?
    • M
      Matthew MoranSep 10, 2025
      If the pressure is below the minimum threshold in your Lowara Water Pump (not present in ACT mode), check the settings of parameters P45 and P46.
  • A
    Andrea JuarezAug 23, 2025
    What to do if my Lowara e-HME Water Pump shows error A20?
    • R
      richard32Aug 23, 2025
      Stop the pump for 5 minutes and then restart it again; if the problem continues, contact Xylem or the Authorised Distributor.
  • P
    Paul WoodsAug 25, 2025
    What to do if my Lowara Water Pump shows a high motor current?
    • M
      Mark PatrickAug 25, 2025
      If your Lowara Water Pump displays a high motor current, stop the pump for 5 minutes and then restart it. If the problem continues, it is recommended to contact Xylem or the Authorised Distributor.
  • E
    Emily BryantAug 26, 2025
    Why is my Lowara e-HME motor overheating?
    • R
      Rebecca WhiteAug 26, 2025
      A motor thermal protection trip in your Lowara Water Pump can occur due to several reasons: * Impurities near the impeller and rotor. * Installation conditions and water/air temperature issues. Check for and remove any impurities. Verify the installation conditions and temperatures. Allow the motor to cool down. If the error persists, stop the pump for 5 minutes, restart it, and if it still continues, contact Xylem or the Authorised Distributor.
  • S
    shannonacevedoAug 27, 2025
    What should I do if my Lowara e-HME Water Pump voltage supply is out of operating range?
    • J
      Juan HopkinsAug 27, 2025
      If your Lowara Water Pump's voltage supply is out of the operating range, check the voltage and the connection of the electric system.
  • M
    Mr. Bradley WhiteheadAug 29, 2025
    What to do if one of the power supply phases is missing in my Lowara Water Pump?
    • A
      ashley04Aug 29, 2025
      If one of the three power supply phases is missing in your Lowara Water Pump (three-phase versions only), check the connection to the power supply network.
  • D
    Dr. Jodi RogersSep 18, 2025
    What to do if my Lowara e-HME Water Pump has a hardware error?
    • Z
      Zachary BakerSep 18, 2025
      If your Lowara Water Pump has a hardware error, stop the pump for 5 minutes and then restart it again. If the problem continues, contact Xylem or the Authorised Distributor.
  • J
    jonesjohnSep 12, 2025
    What causes corrupted multi-pump connection in Lowara e-HME and how to solve it?
    • J
      James JacobsonSep 12, 2025
      A corrupted multi-pump connection in your Lowara Water Pump could be due to: * The condition of the connection cables. * Address discrepancies. Check the condition of the connection cables and ensure there are no address discrepancies.
  • M
    Mckenzie BrownSep 8, 2025
    What to do if the pressure sensor is missing on my Lowara e-HME?
    • K
      kellydarrylSep 8, 2025
      If the pressure sensor is missing on your Lowara Water Pump (not present in ACT mode), check the condition of the sensor connection cables.
  • K
    Kristina PerezSep 5, 2025
    What to check if the frequency converter thermal protection trips on my Lowara Water Pump?
    • J
      Jack McgrathSep 5, 2025
      If the frequency converter thermal protection trips on your Lowara Water Pump, check the conditions of installation and the air temperature.

Summary

1 Introduction and Safety

1.2 Safety

Covers hazard levels, safety symbols, and user safety guidelines.

3 Technical Description

4 Installation

4.1 Mechanical Installation

Covers installation area requirements, unit positioning, and environmental considerations.

4.3 Electrical Installation

Provides requirements for electrical connections, wiring, and grounding.

5 Operation

6 Programming

6.2 Button Functions

Explains the function of each push button on the control panel.

6.5 Software Parameters

Lists and describes various software parameters for unit configuration.

7 Maintenance

Precautions for Maintenance

Essential safety precautions before performing any maintenance operations.

8 Troubleshooting

8.1 Alarm Codes

Lists and explains alarm codes, their causes, and remedies.

8.2 Error Codes

Lists and explains error codes, their causes, and remedies.

Lowara e-HME Specifications

General IconGeneral
TypeHorizontal multistage pump
Maximum Operating Pressure10 bar
Motor Power0.37 kW to 5.5 kW
Protection ClassIP55
Insulation ClassF
Maximum Ambient Temperature40°C
Pump MaterialStainless steel
ApplicationsWater supply, pressure boosting, irrigation, water treatment, heating and air conditioning
MaterialStainless steel
Motor TypeAsynchronous
Power Range0.37 kW to 5.5 kW
Maximum Head80 meters
Voltage230V/400V
Frequency50 Hz