Appendix 1. System Definitions
App1-6
(5) WatchDog timer duration
This parameter is used to set the maximum allowable execution time of a user program in order to supervisor its normal
or abnormal operation.
Only one CPU module can be mounted in the GM7U series, therefore, scan watch dog is valid to only the resource 0.
(6) Input Setting
It’s used to select contact point that will be used for setting input filter or as input pulse catch.
3) Communication parameter
This is a communication parameter to set regular sending/receiving stations, data and cycles to send and receive repeatedly.
(For the detail information about Communication parameter, refer to 7.1.7 Communication parameter setting)
(1) Station No.: 0 to 31
(2) Baud Rate: 1200,2400,4800,9600,19200,38400,57600bps.
(3) Data bit: 7 or 8 bits
(4) Parity bit: None, Even, odd