Chapter 6. Input and Output Specifications
6-16
6.3.4 Expansion module (Relay output)
1) Specifications
Expansion Module
Model
Specifications
G7E-DR08A G7E-DR10A G7E-DR20A G7E-RY08A G7E-RY16A
Output point 4 points 8 points 16 points
Insulation method Relay insulation
Rated load voltage/current
DC24V / 2A (Resistive load), AC220V / 2A (COS Ψ = 1) / 1 point 5A / 1COM
Min. load voltage/current DC5V / 1mA
Max. load voltage/current AC250V, DC110V
Off leakage current 0.1mA (AC220V, 60Hz)
Max. on/off frequency 1,200 times/hr
Surge absorber None
Mechanical More than 20,000,000
Rated on/off voltage/current load 100,000 or more
AC200V / 1.5A, AC240V / 1A (COSΨ = 0.7) 100,000 or more
AC200V / 1A, AC240V / 0.5A (COSΨ = 0.35) 100,000 or more
Service life
Electrical
DC24V / 1A, DC100V / 0.1A (L / R = 7ms) 100,000 or more
Off On
10 ms or lower
Response time
On Off
12 ms or lower
Common 1 point/COM, 2 points/COM
Operation indicator LED is on at on status of output
2) Circuit diagram
It’s the same with the output circuit of the main unit.
3)
Output wiring
DC5V
L
L L
DC24V
AC110/220V
L
L
DC5V/24V
AC110/220V