Chapter 7. Usage of Various Functions
7-103
4) Current position preset (POSPRS)
Function block Description
Input
REQ: Executes POSPRS function block
CH: Sets the channel (0 ~ 1)
PV_VAL: Sets reset value
(-2,147,483,648 ~ 2,147,483,647)
Output
DONE: Turns On after the function block is executed without error, and
turns Off if an error occurs or there is no execution command.
STAT: Displays error status
(1) Functions
Current address is changed to preset value at the rising edge of input condition.
(2) Example program
When input condition (%MX000) turns on, Address of Ch.0 is changed to 100,000.