EasyManuals Logo

LS Industrial Systems STARVERT iG5A User Manual

LS Industrial Systems STARVERT iG5A
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
I0
I1
I2
I3
I4
I5
I6
I7
I8
I9
I10
I11
I12
I13
I14
I15
Jump code
Filter time constant for NV input
NV input Min. voltage
Frequency corresponding to I2
NV input Max. voltage
Frequency corresponding to I4
Filter time constant for V1 input
V1 input Min. voltage
Frequency corresponding to I7
V1 input Max. voltage
Frequency corresponding to I9
Filter time constant for I input
I input Min. current
Frequency corresponding to I12
I input Max. current
Frequency corresponding to I14
0~63
0~9999
0~-10V
0~400Hz
0~-10V
0~400Hz
0~9999
0~10V
0~400Hz
0~10V
0~400Hz
0~9999
0~20mA
0~400Hz
0~20mA
0~400Hz
1
10
0.00
0.00
10.0
60.00
10
0
0.00
10
60.00
10
4.00
0.00
20.00
60.00
Compact & Powerful Inverter iG5A
25
1) Exception SV004iG5A-2/SV004iG5A-4 adopt self-cooling type, so this code is hidden.
Cooling fan control
Operating method select
when cooling fan malfunctions
S/W version
2nd motor Accel time
2nd motor Decel time
2nd motor base frequency
2nd motor V/F pattern
2nd motor forward torque
boost
2nd motor reverse torque
boost
2nd motor stall prevention
level
2nd motor Electronic thermal
level for 1 min
2nd motor Electronic thermal
level for continuous
2nd motor rated current
Parameter read
Parameter write
Parameter initialize
Password register
Parameter lock
H77
H78
H79
H81
H82
H83
H84
H85
H86
H87
H88
H89
H90
H91
H92
H93
H94
H95
0 (Always ON), 1 (Keep ON when its Temp. is higher than Inverter protection limit Temp.)
0 (Run when cooling fan malfunctions), 1 (Stop when cooling fan malfunctions)
0~10.0
0~6000sec
30~400Hz
0 (Linear),1 (Square), 2 (User V/F)
0~15%
30~150%
50~200%
0.1~50A
0~1
0~1
0~5
0~FFFF
0~FFFF
UL (Unlock) Parameter change enable
L (Lock) Parameter change disable
0
0
1.0
5.0
10.0
60.00
0
5
5
150%
150%
100%
26.3
0
0
0
0
0
Yes
Yes
No
Yes
Yes
No
No
No
No
No
Yes
Yes
No
No
No
No
Yes
Yes
Function group 2
LED Parameter
Description
Factory Adj. during
display name default run
Input/output group
LED Parameter
Description
Factory Adj. during
display name default run
1)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LS Industrial Systems STARVERT iG5A and is the answer not in the manual?

LS Industrial Systems STARVERT iG5A Specifications

General IconGeneral
BrandLS Industrial Systems
ModelSTARVERT iG5A
CategoryInverter
LanguageEnglish

Related product manuals